[output_pin probe_enable] pin: gpio29 # The control IO on the SKR 3 is PE5 value: 0 # Probe default retracted [gcode_macro Probe_Deploy] gcode: SET_PIN PIN=probe_enable VALUE=1 [gcode_macro Probe_Stow] gcode: SET_PIN PIN=probe_enable VALUE=0 [probe] pin: ^!gpio22 # The detection IO on the SKR 3 is PC13, V1 should be ^PC13 deactivate_on_each_sample: False x_offset: -26.0 # Actual installed offset of MicroProbe y_offset: -26.5 # Actual installed offset of MicroProbe z_offset: -1.250 # Actual installed offset of MicroProbe speed: 5.0 activate_gcode: Probe_Deploy G4 P500 deactivate_gcode: Probe_Stow [bed_mesh] speed: 300 horizontal_move_z: 10 mesh_min: 27,27 mesh_max: 198,198 fade_start: 0.6 fade_end: 10.0 probe_count: 5,5 algorithm: bicubic [screws_tilt_adjust] screw1: 138.00,138.5 screw1_name: Central screw screw2: 53.00,53.50 screw3_name: Front left screw screw3: 53.00,224.50 screw3_name: Rear left screw screw4: 224.00,53.50 screw4_name: Front right screw screw5: 224.00,224.50 screw5_name: Rear right screw speed: 150 screw_thread: CW-M3 [axis_twist_compensation] speed: 50 calibrate_start_x: 20 calibrate_end_x: 200 calibrate_y: 112.5